GCM-A2 Generator Condition Monitor

GCM-A2 Generator Condition Monitor
GCM-A2 Generator Condition Monitor
Send Inquiry
Product Code : 03
Product Description

Measurement Characteristics

Technology Principle

Ionization Chamber

Flow Rate

Adjusted by internal valve

Differential Pressure

4" to 5" (102 mm to 127 mm) minimum

Bar Graph Readout


Normal Operation

80% of scale, typical

Alarm Condition

50% of scale, typical

Flow

1.5

 

Electrical Characteristics

 

Power - Input Voltage

115/230 VAC

Input Frequency

50/60 Hz

Input Power

100 Watts

Inrush Current

2A

Output Signal

4-20 mA current output, self-powered (0 to 100%)

Flow output signal

4-20 mA current output, self-powered (0 to 3")

Output, Relays

3A @ 250 VAC

Alarm, NO and NC

3A @ 30 VDC resistive

Warning, NO and NC

100 mA @ 125 VDC resistive

Trouble, NO and NC

 

 

Mechanical Characteristics

 

Overall Dimensions

21.8"W x 23.6"D x 30.8"H

Weight

240 lbs. (110 Kg)

Temperature

32-149 F (0-65 C)

Relative Humidity

0-95%

Area Classification

ATEX Zone 2, H2

Gas Pressure

100 psi maximum

Gas Connections

150 lbs., ½" pipe flanges, standard

 